![neplan software download neplan software download](https://www.saashub.com/images/app/screenshots/100/a58514622a81/landing-medium.jpg)
NEPLAN SOFTWARE DOWNLOAD SOFTWARE DOWNLOAD
Characterization of soil with a uniform or multilayer model. Free download neplan software download software at UpdateStar - 1,746,000 recognized programs - 5,228,000 known versions - Software News.Possibility to analyse up to 999 distinct electrodes on the same calculation, including for instance return electrodes, transmission line grounding systems or floating potential underground electrodes.The product will soon be reviewed by our informers. The names of program executable files are Neplan.exe, FEdemo.exe, IE32.exe and SW32.exe. The most popular versions of this product among our users are: 4.2 and 5.3. and is used by 2 users of Software Informer. Analysis of grounding systems of any shape, with choice of the total number of elementary sources NEPLAN is developed by Busarello+Cott+Partner Inc.
![neplan software download neplan software download](https://ieng.tech/wp-content/uploads/2021/11/neplan-banner-1-300x179.png)
Automatic debug of data before calculation.Possibility to import grid layout from “dxf” files.Possibility to consider International (IEC/TS 60479-1:2005), European (EN 50522:2010) and American (IEEE Std 80-2000 and IEEE Std 80-2013) standards.Calculation model based on PEEC method in static conditions.Orthographic projections or isometric representations of grounding system.List of material used for grounding system (wires and rods).Soil surface potentials and touch and step voltages distributions on superficial straight line or rectangular area by 2D and 3D coloured graphic representations, for individuation of safe and hazardous areas.Maximum electric field value close to the electrodes (useful to quickly check if the soil ionization phenomenon can occur).Distribution of leakage current from the electrodes with 1D, 2D and 3D graphical representation to verify the contribution and the efficiency of grounding system portions.Ground resistance and Ground Potential Rise values of all electrodes.With European standard it is also possible to calculate the permissible touch voltage without presence of human body, taking into account the body resistance (Rb 50%) and possibly additional resistance between feet and ground surface Maximum permissible touch and step voltages as per EN and IEEE standards.Reduction factor of touch and step voltages due to a superficial thin layer (Cs) as per IEEE standard.Uniform or multilayer soil model parameters from on site measurements values of apparent resistivity with Wenner or Schlumberger methods.Minimum cross section of grounding system conductors for thermal specification.Split factor (r) as per EN standard or (Sf) as per IEEE standard.Decrement factor (Df) as per IEEE standard.